Repair of Equipment Miele
Repair of household and comm­erc­ial appliances
Book a Technician
CHECK OUT
DURING THE DAY
SPARE PARTS
IN STOCK
ANY TYPE
OF PAYMENT
WE DO COMMERCIAL

Repair Of Miele Coffee Machines

Repair of Miele coffee machines and coffee makers at home in New York with a branded warranty on labor and spare parts.

Services Of The Service Center:

repair of miele coffee machines
  • Post-warranty repair of Miele coffee machines in New York with on-site visits for equipment installation (including at home).
  • Installation, setup, connection, and adaptation of new and used coffee machines of all types.
  • Service maintenance (preventive maintenance) of Miele coffee machines (gasket replacement, brew unit cleaning, descaling, etc.), including warranty extension.
  • Sale of spare parts and consumables for Miele coffee machines and coffee makers from the warehouse in New York, including delivery.
  • Disposal of out-of-service and faulty equipment.

Advantages of our service:

  • Operational Efficiency and Flexible Schedule

    In the vast majority of cases, a request for repairing a coffee machine is fulfilled on the same day as the request. Repairs for standard models like CVA620, CVA2660, CVA5060 typically take no more than 2.5 hours.

    We provide service to remote areas of the New York, neighboring regions, and if needed, we operate in the evening and at night.

  • Repair of Coffee Machines of All Types

    We perform repairs and technical maintenance of coffee machines of all types:

    • Built-in Miele coffee machines: CVA 620, CVA 2660, CVA 5060, CVA 7440, CVA 7845.
    • Freestanding coffee machines: CM 5500, CM 7500.
    • Capsule machines: CVA 4080, and others.
  • Service Call at 0 Rubles

  • Hotline Support

    Consultations on repair, operation, and service maintenance of Miele coffee machines in a 24x7 mode.

  • Brand Warranty

    Official Service Center warranty for Miele coffee machines - up to 24 months. See the "Warranty" section.

Main faults:

  • Does Not Turn On (Not Working)

    Main reasons why the coffee machine does not turn on or is blocked:

    • Faulty power cord or defective plug.
    • Malfunctioning control panel (buttons sticking).
    • Malfunctioning control unit (controller).
    • One possible reason for the blockage is the activation of the thermal protection. In some cases, simply waiting for some time may solve this.
    • Excessive loading. Overloading often leads to a blockage specifically in the brewing unit.
  • Does Not Grind Coffee

    Main reasons why the Miele coffee machine does not grind or grinds coffee poorly:

    • Clogging of the grinders with remnants from previous grinds.
    • Malfunctioning or worn-out gearbox (connection of the auger with the motor).
    • Blades are broken.
    • Malfunctioning electronic block (program module).
  • Does Not Brew Coffee

    Main reasons why the Miele coffee machine does not brew coffee:

    • Coffee is finished or water level is below the minimum allowable.
    • Malfunctioning pressure pump.
    • Malfunctioning temperature sensor.
    • Blockage of the brewing unit: see above, point "does not turn on, blocked".
  • Does Not Heat Water

    Main reasons for the lack of water heating:

    • Heating element failure.
    • Malfunctioning heater power circuit (often due to contact oxidation).
    • Malfunctioning temperature sensor.
    • See also the section "Does Not Brew Coffee".
  • Does Not Froth Milk

    Main reasons why the Miele coffee machine does not froth milk (milk frother not working):

    • Using unsuitable milk (reconstituted from powder or low fat).
    • Clogged steam block or milk frother outlet holes. Alternatively, blockage in the milk delivery system.
    • Malfunctioning or improperly installed dispenser (steam delivery block).
  • Unusual Sounds During Operation ("knocking", "humming", "creaking", etc.)

    Main reasons for unusual noises during coffee machine operation:

    • Clogging of the mesh and filter (characteristic whistle and hissing from under the spout). Less often – blockage in the hot water delivery system.
    • Low level or complete absence of water (characteristic rumbling and sharp crackling).
    • Severe clogging with coffee residues (noticeable holder squeak during espresso brewing).
    • Pump wear or grinding block breakdown (characteristic "metallic" grinding noise).
  • Leakage (water in the drip tray)

    Main reasons for the lack of sealing in Miele coffee machines:

    • Wear or defect in sealing gaskets (most often heater gaskets).
    • Wear of sealing rings (sign - leaks from the drainage valve).
    • Worn or damaged seal ring on the spout.
    • Loose connection of parts – often the result of mechanical impacts (dropping) or incompetent repair.
  • Does Not Fill Full Cup (Overflowing)

    Main reasons why the coffee machine (capsule machine) poorly fills or overflows coffee:

    • Clogging of the brewing unit, boiler, pump, or coffee delivery holes.
    • Wear of the pump.
    • Incorrect dosage regulator adjustment (underfilling and overflowing).
  • Error message

    See Miele Coffee Machine Error Codes or call our Service Center. Call a Technician

Main repair work:

  • Seal Replacement

    (from 600$)
    Seal replacement for Miele coffee machine
  • Pump Repair

    (from 900$)
    Pump repair for Miele coffee machine
  • Hydraulic System Cleaning

    (from 400$)
    Hydraulic system cleaning
  • Cartridge Replacement

    (from 400$)
    Cartridge replacement
  • Drain Valve Replacement

    (from 600$)
    Drain valve replacement for Miele coffee machine
  • Control Board Repair

    (from 1200$)
    Control board repair for Miele coffee machine
  • Gearbox Replacement

    (from 1200$)
    Gearbox replacement for Miele coffee machine
  • Heating Element Replacement

    (from 900$)
    Heating element replacement for Miele coffee machine
  • Grinder Replacement

    (from 900$)
    Grinder replacement for Miele coffee machine
  • Pump Replacement

    (from 900$)
    Pump replacement for Miele coffee machine
  • Brewing Unit Repair

    (from 1200$)
    Brewing unit repair for Miele coffee machine
  • Module Repair

    (40% of the cost of a new one)
    Module repair for Miele coffee machine

Error codes:

  • Main Error Codes for Miele Coffee Machines

    Error code Cause, troubleshooting
    F1

    Water temperature sensor error (NTC sensor): malfunction of the sensor or its short circuit.

    To solve the problem (error 01):

    • Completely disconnect the coffee machine from the electrical network for half an hour, then reconnect it.
    • Check the NTC sensor.
    • Check the sensor connectors.
    F2

    Water temperature sensor error (NTC sensor): sensor malfunction or breakage in its connection circuits.

    To solve the problem (error 02):

    • Completely disconnect the coffee machine from the electrical network for half an hour, then reconnect it.
    • Check the NTC sensor.
    • Check the sensor connectors.
    F3

    Steam temperature sensor error (NTC steam sensor): sensor malfunction or its short circuit.

    To solve the problem (error 03):

    • Completely disconnect the coffee machine from the electrical network for half an hour, then reconnect it.
    • Check the NTC steam sensor.
    • Check the sensor connectors.
    F4

    Steam temperature sensor error (NTC steam sensor): sensor malfunction or breakage in its connection circuits.

    To solve the problem (error 04):

    • Completely disconnect the coffee machine from the electrical network for half an hour, then reconnect it.
    • Check the NTC steam sensor.
    • Check the sensor connectors.
    F10

    Water supply error.

    Insufficient water filling speed is registered within a certain time, or the filling is completely absent.

    To solve the problem (error 10):

    • Remove the water tank, empty it, and reinstall it (there might be an airlock, this procedure solves the issue).
    • Check the level sensor (it might be stuck in the lower position).
    • Check the flow meter.
    • Check the water pump (possible malfunction of the pump or its connection circuits).
    F17

    Water supply error.

    Insufficient water filling speed is registered.

    To solve the problem (error 17):

    • Completely disconnect the coffee machine from the electrical network for 2 minutes, then reconnect it.
    • Check the correct installation of the water tank.
    • Check the water intake valve filter (possible clogging).
    • Check the water pump (possible malfunction of the pump or its connection circuits).
    F28, "Too much ground coffee"

    Tray overflow error.

    Excessive tray filling is registered.

    After registering this malfunction, excess coffee is discharged into the waste container, and the program is prematurely interrupted with the display of the specified error.

    To solve the problem (error 28):

    • Remove the brewing unit, clean it, and the waste container.
    • Use a smaller amount of coffee during loading.
    F41

    Control unit error.

    An error in reading the EEPROM (Electrically Erasable Programmable Read-Only Memory) is registered.

    To solve the problem (error 41), try completely disconnecting the coffee machine from the electrical network for several minutes, then reconnect it. If the error persists, the controller needs repair at the component level (replacement or reprogramming of the EEPROM chip).

    F42

    Power supply error.

    Deviation in the frequency of the supply voltage by more than 5 Hz is registered.

    To solve the problem (error 42):

    • Turn off the coffee machine until the power supply returns to normal operation.
    F45

    Control unit error.

    An error in reading the Flash memory is registered.

    To solve the problem (error 45), try completely disconnecting the coffee machine from the electrical network for several minutes, then reconnect it. If the error persists, the controller needs repair at the component level (usually replacing the Flash memory chip).

    F71

    Capsule mechanism error.

    To solve the problem (error 71):

    • Check the functionality of the capsule mechanism.
    F72

    Capsule mechanism error.

    Damage or deformation of the capsule is registered.

    To solve the problem (error 72):

    • Remove the damaged capsule.
    F73,
    "Check brew unit"

    Brewing unit error.

    Incorrect drive operation is registered. The error often occurs due to incorrect installation of the brewing unit or a malfunction in the drive.

    To solve the problem (error 73):

    • Turn off the coffee machine.
    • Remove and clean the brewing unit.
    • Set the coffee dispensing device to the correct position.
    • Clean the water and waste containers.
    • Turn on the coffee machine (without the brewing unit). The brewing block will initialize. When "Insert the brew unit" appears, open the front panel and reassemble all parts.
    F74

    Ceramic valve error.

    Incorrect operation of the ceramic valve is registered. The error often occurs due to a malfunction in the valve itself or its drive.

    To solve the problem (error 74):

    • Completely disconnect the coffee machine from the electrical network for 2 minutes, then reconnect it.
    • Check the condition of the valve and its drive.
    F75, F76

    Brewing unit error.

    An error in automatic ejection of the capsule after coffee preparation is registered.

    To solve the problem (error 75, 76):

    • Turn off the coffee machine.
    • Remove the stuck capsule.
    F77

    Ceramic valve initialization error.

    To solve the problem (error 77):

    • Completely disconnect the coffee machine from the electrical network for 2 minutes, then reconnect it.
    • Check the valve functionality.
    F80

    Heating error.

    The required water temperature was not reached within the allotted time.

    To solve the problem (error 80):

    • Completely disconnect the coffee machine from the electrical network for 2 minutes, then reconnect it.
    • Check the water temperature sensor.
    • Check the heating element (possible malfunction or excessive scale deposits).
    F82

    Heating error.

    An exceedance of the maximum allowable water temperature is registered.

    To solve the problem (error 82):

    • Completely disconnect the coffee machine from the electrical network for 2 minutes, then reconnect it.
    • Check the water temperature sensor.
    • Check the heating element and power circuits.
    F225, F226, F235, F236

    Internal error.

    • Completely disconnect the coffee machine from the electrical network for 2 minutes, then reconnect it.
    F227, F228, F229, F230

    Automatic dosing regulation error.

    To reset (errors 227, 228, 229, 230):

    • Completely disconnect the coffee machine from the electrical network for 2 minutes, then reconnect it.
    F233

    Dosing error.

    An incorrect installation of the cup edge sensor is registered.

    To solve the problem (error 233):

    • Completely disconnect the coffee machine from the electrical network for 2 minutes, then reconnect it.
    • Check the cup edge sensor installation.
    • Install the steel lining cover.
    F234

    Dosing error.

    The third triggering of the overflow protection is registered: the automatic dosing regulation (ADR) could not correctly recognize the used containers (a system ADR failure may be the case).

    To solve the problem (error 234):

    • Change the used container.
    • Completely disconnect the coffee machine from the electrical network for 2 minutes, then reconnect it.
    F307

    Milk dispensing error.

    To solve the problem (error 307):

    • Check the milk dispensing valve (possible malfunction or blockage).
    • Completely disconnect the coffee machine from the electrical network for 2 minutes, then reconnect it.
    «Check water intake»

    Water intake error.

    An error in the water supply system is detected.

    To solve the problem (error «Check water intake»):

    • Check the water intake hose (possible deformation or blockage).
    • Verify the correct installation of the water container.
    «Push the water container in until it engages»

    Water container installation error.

    To solve the problem:

    • Check the correct installation of the water container.

    In the event this message appears during decalcification, refill the container with water and restart the descaling process.

Determine the cause of the breakdown and the full cost of repair:

Question and Answer:

  • Hello. The built-in coffee machine CVA 4060 shows error 73 upon startup, what could be the issue?

    You didn't mention what caused this error. Often such details help to more accurately determine the cause of the malfunction.

    In general, the problem might lie in the installation of the brewing unit. Try reinstalling it by following these steps:

    • Remove and clean the brewing unit (Refer to the "Cleaning and maintenance - Brewing device" section in the user manual).
    • Take out the waste container (it's also beneficial to clean it) and the water container.
    • Close the coffee machine and turn it on using the power button. The device will initialize, and the display will show "Insert the new unit."
    • Now, open the panel, install all the parts, and turn it on.

    In some cases, error 73 occurs due to a drive malfunction. If you cannot resolve the issue on your own, contact the Service Center.

  • Coffee machine CVA 5060 shows error F10. What can I do on my own?

    In general, error 10 is a water supply error. Try turning off the coffee machine, removing the water container, wait for some time, then place it back, and turn the coffee machine on again.

    If the error reoccurs, contact the Service Center. It might be a malfunction of the flow meter or water pump.

  • What causes the Miele coffee machine to display error F17?

    Error 17 is a water supply error, specifically, a lack of pressure.

    The main reasons for this error include incorrect installation of the water container or blockage in the supply line. In the latter case, check the filter of the water intake valve and replace it if necessary.

  • Error F233 in Miele coffee machines: causes and troubleshooting methods?

    Error 233 is a dosing unit error: the edge sensor of the cup is incorrectly positioned.

    To resolve the problem, turn off the coffee machine for several minutes, remove the stainless-steel cladding cover (on most models), then turn the coffee machine back on and position the cup edge sensor according to the instructions for your machine.

YOUR QUESTION

Reviews:

  • Thank you.

    I'll be brief. I had the brewing unit of my Miele CVA 5060 repaired, and the repair cost was quite satisfactory.

    (27.01.2022)
  • Very expensive parts.

    I'm writing a review because I'm outraged by the prices for repairs, not of this service, but of our German friends who supply spare parts for their Miele coffee machines.

    It's been in use for over 12 years, but for this technology, it's not such a long time, and we encountered a bunch of malfunctions during the repair. No one in the store explained to us during the purchase that we need to constantly service our coffee machine just like a car.

    The rating is not for this service but for the Miele company!

    (09.01.2022)
  • Thank you.

    Thank you for the quality repair of our CVA5060 coffee machine.

    We've made an agreement for further service.

    We'll stay with you.

    (03.12.2021)
  • Thank you.

    The entire team of our business center expresses gratitude to the employees of this service, and special thanks to Victor (the master of coffee machine repair and maintenance).

    For over three years, we have been using your service, and our Miele coffee machines have never let us down: every morning we drink coffee and remember your company with kind words.

    (08.10.2021)
  • Awesome Service.

    Leaving feedback for the first time because I'm pleased with the repair time of my Miele CVA4050.

    Just as the visiting technician promised, they brought the machine back to working condition within two business days. They delivered, installed it, and everything is functioning perfectly.

    Simply awesome service.

    (22.06.2021)
  • Recommendation.

    Our large family cannot start the day without coffee! This is the second time we've called specialists from Miele Service 24 for the preventive cleaning of our CVA620.

    We would like to highlight both the high-quality service and promptness. We highly recommend it.

    (05.03.2021)
WRITE A REVIEW

Any other questions? Order a callback. The response time is less than a minute.

Save
-10%